Version 3 (modified by wja, 3 months ago) (diff)

--

2023 Installations

The 2023 campaign saw four differnt configorations of instruments on board the VP-FBL Twin Otter in Italy, UK and Canada.

Instrument Orientations

Note: I believe that the IMU being "backwards" is the way our processing systems expect it.

InstallationJulian RangeIMUOwlFenix1kIbisPhaseOne
Italy 1143 - 152BackwardsBackwardsBackwardsForwardsForwards
Italy 2 176 - 183BackwardsBackwardsBackwardsForwardsForwards
UK190 - 200ForwardsNot InstalledBackwardsForwardsForwards
Canada226-235ForwardsForwardsBackwardsForwardsForwards

The following should outline the data from which instruments which requires across-sample flipping in order to map.

InstallationJulian RangeOwlFenix1kIbis
Italy 1143 - 152 flip
Italy 2 176 - 183 flip
UK190 - 200 flip
Canada226-235 flip

Boresight Values

InstallationJulian RangeOwlFenix1kIbis